Applications

Aerial Bundle Cables, often referred to as Aerial Bundled Conductors or simply ABC Cable, are cables for overhead line power, so called for combining multiple single core cables together. Its mainly applications are:

●  For distribution low power overhead networks in metropolitan,urban and rural areas;  

●  For supply of remote facilities and villages of temporary and permanent character;

●  For above-ground house connections.

 In temporary power installations such as on construction sites

 For any more information or advice please contact the office on 0086-18832134509 (WhatsApp/WeChat)

Share:

Details

Overview

Copper Overhead Service Drop Cable Wires

overhead cable is a special cable manufactured using a process similar to that of cross-linked cables. it is a new way of transmitting electricity between overhead conductors and underground cables. overhead cables are widely used in power transmission at home and abroad. Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures of 75 ºC for polyethylene  insulated conductors,90°C for crosslinked polyethylene (XLP) insulated conductors. It is ideal for use in urban areas with congested power distribution and narrow lanes and by-lanes . The flexible system is much easier than conventional overhead power lines to re-route when demanded by changes in urban development plans. And generally overhead insulated cables are high-voltage lines , so if they are very close to buildings, they must choose overhead insulated cables.Aerial Bundled Conductor cables can be used to replace bare conductor cables in overhead distribution systems.

Construction

Copper Overhead Service Drop Cable Wire 

Description:  Overhead Service Drop Cable Wires  

Conductor:  Class 2 Stranded Copper Conductor

+N-:  With Messenger Core

Insulation:  HDPE or XLPE Insulation

Insulation Color: Black

Rated Voltage (Uo/U): 0.6/1KV

 

Physical Properties

Maximal operating conductor Temperature: up to 75(HDPE insulation) 90(XLPE insulation)

Minimum Temperature for cable laying: -5℃(XLPE insulation)

Short Circuit Temperature(5 seconds maximum duration): 250℃(XLPE insulation)

Technical Data

<td Length"> Standard
Length

PHYSICAL PROPERTIESELECTRICAL PROPERTIES
Cable SizeInsulation
Thickness
Approx Twisted
Diameter
Approx.
Net.Weight
Max.Conductor
Resistance at 20
Current Carrying
Capacity at 35℃
Calculated
Breaking Force
Standard Length
  mm²   mm  mm  Kg/km  Ω/km  A  kg  m
2x6rm1.2 13.0 136 3.080 54 394 2000 
2x10rm1.2 14.0 211 1.830 73 656 2000 
2x16rm1.2 16.0 334 1.150 97 1,0511000 
4x6rm1.2 15.7 258 3.080 54 788 1000 
4x10rm1.2 170 422 1.830 73 1,3121000 
4x16rm1.2 190 6401.150 97 2,1021000 
4x25rm1.4 240 1,0080.727 133 3,2841000 